新型利废自保温混凝土砌块墙体抗震性能试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
自保温混凝土砌块作为节能与结构一体化的新型建筑材料,它具有轻质高强、节能保温等优点。本文通过试验及理论研究,探讨了自保温混凝土砌块墙体的抗震性能以及竖向荷载对墙体破坏特征和抗震性能的影响,研究结果可为自保温混凝土砌块砌体结构的应用提供参考。
The new waste utilization self-insulation concrete block is a new building material which insulation and structure performance are integrated. Based on the experimental and theoretical study,the seismic performance of the self-insulation concrete masonry is discussed. This object is to study the seismic performance of a kind of block wall in the form of self-insulation,and vertical load effects on wall failure characteristics and seismic performance. It provides a reference to the application of this material.
引文
[1]李兆龙.建筑节能问题研究[J].今日科苑,2009(10):137-138.
    [2]涂逢祥.21世纪初建筑节能展望[J].新型建筑材料,2001(1):32-35.
    [3]王剑.节能利废型自保温混凝土配合比及耐久性试验研究[D].南京:南京工业大学,2012.
    [4]JGJ55—2011普通混凝土配合比设计规程[S].
    [5]朱伯龙.结构抗震试验[M].北京:地震出版社,1989.
    [6]田玉滨,唐岱新.配筋砌体开洞剪力墙抗震性能的试件研究[J].哈尔滨工业大学学报,2002(4):20-24.
    [7]唐岱新,王凤来,施楚贤.新型砌体结构体系与墙体材料——配筋砌块砌体研究成果汇编[M].北京:中国建筑工业出版社,2010.
    [8]杨春侠,施楚贤.混凝土多孔砖砌体结构恢复力模型研究[J].长沙交通学院学报,2007(4):1-6.
    [9]郭子雄,杨勇.恢复力模型研究现状及存在问题[J].世界地震工程,2004(4):47-51.
    [10]杨春侠,施楚贤.混凝土多孔砖砌体结构恢复力模型研究[J].长沙交通学院学报,2007(4):1-6.
    [11]王辰宇.预应力混凝土小型空心砌块砌体抗震性能试验研究[D].南京:南京工业大学,2005.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心