  • 关键词:铁碳微电解系统 ; 模拟含磷废水 ; TP去除率
  • 英文关键词:Iron-carbon microelectrolysis system;;Simulated phosphorus-containing wastewater;;TP removal;;Removal rate
  • 中文刊名:西南科技大学学报
  • 英文刊名:Journal of Southwest University of Science and Technology
  • 机构:西南科技大学环境与资源学院;西南科技大学低成本废水处理技术四川省国际科技合作基地;
  • 出版日期:2019-03-31
  • 出版单位:西南科技大学学报
  • 年:2019
  • 期:01
  • 基金:四川省科技计划项目(2017SZ0084);; 四川省教育厅科研基金项目(18ZB0605)
  • 语种:中文;
  • 页:42-47
  • 页数:6
  • CN:51-1640/N
  • ISSN:1671-8755
  • 分类号:X703
摘要
采用自配模拟含磷废水,通过批实验和正交实验探讨影响铁碳微电解系统对废水中TP去除效果的因素及其适宜因素值组合。研究结果表明:当废水初始TP浓度为5 mg/L,活性炭加入量为0. 03 g/m L时,在其pH值为3. 0,搅拌强度为110 r/min的条件下,吸附至25 min时,活性炭对模拟废水中TP的吸附基本达到饱和,其对TP的吸附去除率在19. 8%左右。不考虑活性炭对模拟废水中TP的吸附作用,单因素影响的研究表明,铁碳微电解系统对废水中TP去除效果较好的适宜pH值为3. 0,铁碳比为1∶1. 5,搅拌强度为110 r/min;正交实验显示,各因素对铁碳微电解系统去除TP影响程度由大到小的顺序依次为:初始pH值>铁碳质量比>反应时间>搅拌强度。采用最佳参数组合的铁碳微电解系统对废水中TP的去除率为20. 91%。
        Artificially prepared phosphorus-containing wastewater was used to study the influencing factors for the removal of total phosphorus( TP) through batch experiments and orthogonal experiments by an iron-carbon micro-electrolysis system. The results show that when the initial TP concentration of wastewater is 5 mg/L and the activated carbon is 0. 03 g/m L,the pH value of the wastewater is 3. 0 and the stirring intensity is 110 r/min,the TP adsorption by activated carbon reaches saturation basically in simulated phosphorus-containing wastewater when it is adsorbed for 25 min,and its adsorption removal rate of TP isabout 19. 8%. The study of different single-factor effects shows that the suitable pH value for iron-carbon micro-electrolysis system to remove TP in wastewater is 3. 0,the ratio of iron to carbon is 1∶ 1. 5,and the stirring intensity is 110 r/min. Orthogonal experiments show that the affecting factors of the TP removal from the iron-carbon microelectrolysis system follows this order: initial p H value > iron-carbon mass ratio >reaction time > stirring intensity. The removal rate of TP is 20. 91% in wastewater by iron-carbon microelectrolysis system with the best combination of parameters.
引文
[1]陈华.化学沉淀法除磷和生物法除磷的比较[J].上海环境科学,1997,16(6):33-35.
    [2]贾晓燕.废水除磷技术的研究进展[J].重庆环境科学,2003,25(12):191-192.
    [3]顾小红,黄种买.污水除磷技术的现状及发展趋势[J].中国再生资源,2002,40(3):33-35.
    [4]徐丰果,罗建中,凌定勋.废水化学除磷的现状与进展[J].工业水处理,2003,23(5):18-20.
    [5]丁文明,黄霞.废水吸附法除磷的研究进展[J].环境工程学报,2002,3(10):23-27.
    [6]杨林,宋鑫,王玉军,等.微电解预处理靛蓝牛仔布印染废水[J].环境工程学报,2013,7(1):268-272.
    [7]ZHANG Y T,LUN H B.Research on micro-electrolysis method to treat the chrome-containing steel wastewater[J].Applied Mechanics&Materials,2013,448-453:620-624.
    [8]冯雅丽,张茜,李浩然,等.铁炭微电解预处理高浓度高盐制药废水[J].环境工程学报,2012,6(11):3855-3860.
    [9]李海松,闫阳,买文宁,等.铁碳微电解-H2O2耦合联用的类Fenton法处理制浆造纸废水[J].环境化学,2013,(12):2302-2306.
    [10]谭南中,李德生,洪飞宇,等.国内铁炭微电解预处理有机废水的研究进展[J].广州化工,2010,38(5):62-64.
    [11]雍文彬,孙彦富,陈震华,等.铁屑微电解法处理农药废水的研究[J].环境污染治理技术与设备,2002,3(3):86-87,64.
    [12]国家环境保护局《水和废水监测分析方法》编委会.水和废水监测分析方法,第四版[M].北京:中国环境科学出版社,2002.
    [13]EL-ASHTOUKHY E S Z.Removal of lead(II)and copper(II)from aqueous solution using pomegranate peel as a new adsorbent[J].Desalination,2008,223(1-3):162-173.
    [14]FENG J.Removal of EDTA-chelated copper from aqueous solution by interior microelectrolysis[J].Separation&Purification Technology,2011,78(1):33-41.
    [15]乔鹏,张毅,黄天寅,等.铁碳微电解预处理强酸高盐印染中间体废水[J].环境工程学报,2015,9(10):4717-4723.
    [16]赖鹏,赵华章,王超,等.铁炭微电解深度处理焦化废水的研究[J].环境工程学报,2007,(3):15-20.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700