用户名: 密码: 验证码:
改变给药次序对提高子宫输卵管超声造影诊断符合率的研究价值
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Value of changing the order of administration in improving diagnostic coincidence rate of hysterosalpingography
  • 作者:梁洁梅 ; 殷红霞 ; 孔晓玲 ; 韦兴来 ; 杨宇璐 ; 晏湘梅
  • 英文作者:LIANG Jie-mei;YIN Hong-xia;KONG Xiao-ling;Department of Ultrasonography,Guangxi Yulin First People’s Hospital;
  • 关键词:给药次序 ; 造影剂 ; 混合液 ; 输卵管造影
  • 英文关键词:Order of administration;;Contrast agent;;Mixed solution;;Fallopian tube angiography
  • 中文刊名:ZSSA
  • 英文刊名:China Practical Medicine
  • 机构:广西玉林市第一人民医院超声科;
  • 出版日期:2019-03-10
  • 出版单位:中国实用医药
  • 年:2019
  • 期:v.14
  • 语种:中文;
  • 页:ZSSA201907041
  • 页数:3
  • CN:07
  • ISSN:11-5547/R
  • 分类号:76-78
摘要
目的探讨改变给药次序对提高子宫输卵管超声造影诊断符合率的研究价值。方法 400例因不孕到本院妇产科就诊并行子宫输卵管超声造影的患者为研究对象,随机分为A组和B组,每组200例。在不改变药物及剂量的前提下, A组患者先注入混合液后打造影剂, B组患者先打造影剂后注入混合液。比较两组患者的诊断符合率。结果 A组患者中由于异位妊娠已手术切除一侧输卵管10条,腹腔镜下美兰通液术诊断390条输卵管,其中输卵管通畅160条,通而不畅178条,阻塞52条。子宫输卵管超声造影检查符合343条,诊断符合率为87.9%。B组患者中由于异位妊娠已手术切除一侧输卵管15条,腹腔镜下美兰通液术诊断385条输卵管,其中输卵管通畅153条,通而不畅150条,阻塞82条。子宫输卵管超声造影检查符合357条,诊断符合率为92.7%。B组患者的诊断符合率高于A组,差异具有统计学意义(P<0.05)。结论先注入造影剂后注入混合液的造影给药方式可提高子宫输卵管超声造影的诊断符合率。
        Objective To discuss the research value of changing the order of administration in improving diagnostic coincidence rate of hysterosalpingography. Methods A total of 400 cases of infertility patients in gynecology and obstetrics department for hysterosalpingography as study subjects, were randomly divided into group A and group B, with 200 cases in each group. Without changing the drug and dosage, group A was injected with mixed solution before shadowing agent, group B was injected with mixed solution after shadowing agent. The diagnostic coincidence rate in two groups was compared. Results In group A, 10 fallopian tubes had been removed because of ectopic pregnancy, and 390 fallopian tubes were diagnosed by laparoscopic Melan hydrotubation, of which 160 tubes were unobstructed, 178 tubes were partially obstructed and 52 tubes were obstructed. There were 343 accorded tubes by hysterosalpingography, and the diagnostic coincidence rate was 87.9%. In group B, 15 fallopian tubes were resected and 385 fallopian tubes were diagnosed by laparoscopic Melan hydrotubation. Among them, 153 tubes were unobstructed, 150 tubes were partially obstructed and82 tubes were obstructed. There were 357 accorded tubes by hysterosalpingography, and the diagnostic coincidence rate was 92.7%. Group B had higher diagnostic coincidence rate than group A, and the difference was statistically significant(P<0.05). Conclusion The diagnostic accuracy of hysterosalpingography can be improved by injecting mixed solution after shadowing agent.
引文
[1]陈欣,罗红.子宫输卵管超声造影术对于临床诊断输卵管堵塞所致不孕症的研究进展.中华妇幼临床医学杂志(电子版),2016, 12(4):479-483.
    [2]程琦,王莎莎,朱贤胜,等.经阴道子宫输卵管四维超声造影评估输卵管的通畅性.中国医学影像技术, 2013, 29(3):455-458.
    [3]王伟群,张金山,周秋兰,等.四维子宫输卵管超声造影教学模式的探讨.临床超声医学杂志, 2018, 20(10):712-713.
    [4]熊维,应涛.输卵管超声造影的临床应用及研究进展.中华医学超声杂志(电子版), 2016, 13(11):872-874.
    [5]Zhou L, Zhang X, Chen X, et al. Value of three-dimensional hysterosalpingo-contrast sonography with SonoVue in the assessment of tubal patency. Ultrasound in Obstetrics&Gynecology,2012, 40(1):93-98.
    [6]刘婷,聂芳,吴闯,等.实时三维子宫输卵管超声造影评价输卵管通畅性.中国医学影像技术, 2018, 34(7):1059-1062.
    [7]郑荣琴.妇科超声造影临床应用指南.中华医学超声杂志(电子版), 2015, 12(2):94-98.
    [8]张雁.经阴道实时三维输卵管造影技术的临床应用//中华医学会超声医学分会.中华医学会第十三次全国超声医学学术会议论文汇编, 2013:1.
    [9]徐虹,汪龙霞,罗渝昆,等.子宫输卵管三维超声造影检查在不孕症诊断中的临床价值.中华医学超声杂志(电子版), 2011,8(12):2578-2584.
    [10]郭俊,王莎莎,程琦,等.经阴道实时三维子宫输卵管超声造影剂逆流分析.中国医学影像技术, 2014, 30(7):1063.
    [11]张婧.超声引导下子宫输卵管造影术耐受性和安全性评估及相关因素探讨.江苏大学, 2016.
    [12]王小倩,孙志伟,王琳,等.经阴道实时三维子宫输卵管超声造影耐受性及造影相关疼痛因素分析.临床超声医学杂志, 2018,20(6):417-419.
    [13]查晓霞,邓晓杨,游岚岚,等.子宫输卵管超声造影检查患者副反应的临床分析.临床超声医学杂志, 2017, 19(3):182-185.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700