摘要
文章采用CFD(计算流体力学)数值模拟的研究方法,探究了孤立街道峡谷内不同屋顶形状和污染源位置的数值仿真模型。针对平顶-三角形屋顶和三角形-平顶屋顶,以及3种污染源,共6种工况进行研究。结果表明相同屋顶形状的污染源位置变化对于气流运动无改变,对于污染物浓度相对低的壁面浓度值改变很小,但对污染物浓度相对高的壁面浓度有较大影响,街谷上部靠近屋顶位置受污染源位置的影响逐步减小。
The article adopts of CFD numerical simulation method,to explore the influence of the verious roof shapes and pollutant source location on wind flow in street cayon.6 conditions are considered in total which related flat-triangle and triangle-flat roof as well as three different roof type.The results show that the pollutant source locations have no effect on the air flow in street cayon.And t has less influence on the low concentration values on the wall,where more remarkable influence on the high concentration values on the wall.
引文
[1]李滨丹,吴宁.探讨汽车尾气污染危害与对策[J].环境科学与管理,2009,34(7):174-177.
[2]Kumar P,Fennell P,Britter R.Measurements of particles in the 5–1000 nm range close to road level in an urban street canyon[J].Science of the Total Environment,2008,390(2-3):437-44.
[3]Huang Y D,Jin M X,Sun Y N.Numerical studies on airflow and pollutant dispersion in urban street canyons formed by slanted roof buildings[J].Journal of Hydrodynamics,Ser B,2007,19(1):100-106.
[4]黄远东,李文孟.带斜顶建筑物的城市街道峡谷内部气流场数值研究[J].合肥工业大学学报(自然科学版),2005,28(10):1317-1320.
[5]李沁怡,蔡旭晖,康凌.建筑扰动条件下大气流动与扩散的CFD模拟[J].环境科学研究,2013,08:829-837.
[6]Fluent Inc.FLUENT User’s Guide[M].Fluent Inc,2003.
[7]Kastner-Klein P,Plat e E J.Wind-tunnel study of concentration fields in street canyons[J].Atmos Environ,1999,33:3973.