The Application of LaBr3(Ce) Gamma Radiation Scintillation Spectrometer to Direct Determination of Uranium Content of Uranium Ore Bodies
详细信息   
摘要
Lanthanum bromide scintillator,namely LaBr3(Ce),is a new detector which has excellent comprehensive performance for detecting gamma-ray.However,LaBr3(Ce) detector fails to measure the fine structure of gamma-ray spectrum from the uranium-bearing ore body for its limited energy resolution,and the spectrum measured doesn’t show the characteristic peaks which are directly related to uranium content.Under such circumstances,the development of a technique which can determine uranium content directly is necessary.The authors measured a series of hard rock radionuclide-bearing ore bodies using a LaBr3(Ce) probe made in China,and determined uranium content directly by relative analysis combining energy window with linear regression based on 234Pam,1.001 MeV characteristic energy and,as a result,obtained satisfactory results,which show that the relative error is less than 10.0% for uranium content over 99×10-6,and the error is less than 8.5% for other main radionuclides.