电力系统地震功能失效有两种方式,一是物理功能失效,二是供电流功能失效。对系统供电流功能失效进行了深入的研究。首先用模糊矩阵对受地震干扰的系统进行连通性分析,之后运用灵敏度安全法对系统进行安全性分析。该方法是将因地震引起的电力供应系统线路开断视为系统正常运行的一种扰动,从系统供电流方程的Taylor级数展开式出发,得到灵敏度矩阵,以系统节点注入的功率增量来计算系统运行变量增量,为判断系统运行状态提供依据。最后结合一个实例验证了该方法的实用性,该工作可作为电力系统地震功能失效分析的理论基础,为电力系统地震防灾和工程加固提供理论依据。
There are two modes of seismic function failure on a power supply system,the first is physical function failure and the other is load flow function failure.The load flow function failure is studied in-depth.The system′s connectivity is analyzed by fuzzy matrix firstly,then the sensitivity analysis method is employed for safe analysis.In this method the line outage is viewed as disturbance of the system in normal running condition.The sensitivity matrix is got from the Taylor series expansion of the electric power system equation,and the running parameter increments are got from the systems power increments by the matrix.It could provide a basis for judging the system′s running state.At last the practicality of the method is verified by an example.All the above can be applied as theoretical basis for power supply system security analysis and can provide theoretical basis for earthquake disaster prevention and structure strengthening.
引文
[1]李杰.生命线工程抗震理论与应用[M].北京:科学出版社,2005.Li Jie.Lifeline Earthquake Engineering—Basic Methods and Applications[M].Beijing:Science Press,2005.
    [2]柳春光,林均岐.电力系统地震功能失效数值模拟与控制分析[J].地震工程与工程震动,2009,29(5):147-152.Liu Chunguang,Lin Junqi.Computer simulation and flow load control of seismic function failure analysis of power system[J],Journal of Earth-quake Engineering and Engineering Vibration,2009,29(5):147-152.
    [3]柳春光,林皋,李宏男,等.生命线地震工程导论[M].大连:大连理工大学出版社,2005.Liu Chunguang,Lin Gao,Li Hongnan,et al.Introduction to Lifeline Earthquake Engineering[M].Dalian:Dalian University of TechnologyPress,2005.
    [4]日本阪神大地震考察组.日本阪神大地震可靠性报告[M].北京:地震出版社,1997.The Investigation Group of Osaka-Kobe Earthquake,The Report of Osaka-Kobe Earthquake in Japan[M].Beijing:Earthquake Press,1997.
    [5]何双华.供水管网系统抗震可靠性分析及加固优化研究[D].大连理工大学,2009.He Shuanghua.Research on seismic reliability and optimum restrofit of water supply nelwork system[D].Dalian:Dalian University of Technology,2009.
    [6]李秀菊.供电系统地震功能失效分析[D].哈尔滨,中国地震局工程力学研究所,2000.Li Xiuju.Studies on seismic function failure of electric power supply system[D].Harbin:Institude of Engineering Machanics,2000.
    [7]王锡凡,方万良,杜正春.现代电力供应系统分析[M].北京:科学出版社,2003.Wang Xifan,Fang Wanliang,Du Zhengchun.Analysis of Modern Power System[M].Beijing:Science Press,2003.
    [8]王锡凡,王秀丽.实用电力供应系统静态安全分析[J].西安交通大学学报,1988,22(1):25-36.Wang Xifan,Wang Xiuli.Practical contingency analysis of power system[J].Journal of Xi'an Jiaotong University,1988,22(1):25-36.
    [9]GB12325-90,电能质量供电电压允许偏差[S].GB12325-90,Power Quality—Admissible Deviation of Supply Voltage[S].
    [10]柳春光,李光华,林均岐.电力供应系统地震安全分析与控制对策研究[J].地震工程与工程振动,2010,30(3):11-17.Liu Chunguan,Li Guanghua,Lin Junqi.Research on seismic security analysis and control countermeasure of power supply system[J].Journal ofEarthquake Engineering and Engineering Vibration,2010,30(3):11-17.
    [11]柳春光,李秀菊.电力供应系统地震功能失效问题研究[J].地震工程与工程振动,2003,23(2):159-166.Liu Chunguang,Li Xiuju.Studies on seismic function failure of electric power supply system[J].Journal of Earthquake Engineering and Engi-neering Vibration,2003,23(2):159-166.
    [12]Vanzi I.Seismic reliability of electric power networks:methodology and application[J].Structural Safety,1996,18(4):311-327.
    [13]美国地震工程协会著.洛马普里埃塔地震考察[M].北京:地震出版社,1991.American Earthquake Engineering Association.The Loma Prieta Earthquake Investigation[M].Translated by the Seismic Office of China Petrole-um and Chemical Corporation(sinopec).Beijing:Earthquake Press,1991.
    [14]EERI.Loma Prieta earquake reconnaissance report[J].Earthquke Spectra,1999,6(Suppl.).
    [15]李光华.电力供应系统地震功能失效分析与安全控制研究[D].大连:大连理工大学,2010.Li Guanghua.Research on seismic function failure analysis and security control of power supply system[D].Dalian:Dalian University of Tech-nology,2010.