用户名: 密码: 验证码:
电动汽车驱动电机定子接线故障分析与检测
详细信息    查看官网全文
摘要
以一台故障电机为研究对象,通过测试和排查,初步确定了是电机定子线圈接线故障,并仿真分析了若干可能出现故障类型,计算结果特征与试验相符;其后,在电机定子绕组拆解修复工作中确认具体故障类型和发生缘由;最后,通过利用脉冲线圈测试仪比对检测件与标准件衰减波形特征,检测出接线故障的定子总成,避免类似接线故障再次发生。
For a failing motor,initially identified the failure is stator coil wiring fault through testing and troubleshooting.And a number of possible fault types were analyzed,the calculation results are consistent with the experimental features;Then confirm the specific fault type and cause of the occurs in the motor stator windings through dismantling and repair work;Finally,by using a pulse coil tester,contrast detection member and standard' s attenuation waveform feature,to avoid similar wiring fault occurs again.
引文
[1]乔长君.电机绕组接线图册[M].北京:化学工业出版社,2009.
    [2]汤蕴璆.电机学[M].北京:机械工业出版社,2011.
    [3]刘卉圻,韩坤,苟斌,葛兴耒,冯晓云.异步电机定子绕组匝间短路故障建模与分析[J].机车电传动,2013(6),52-55.
    [4]徐晓玲,彭伟发,陆荣秀.电机定子绕组故障容错控制概述[J].微特电机,2015(3):81-85.
    [5]魏书荣,符杨,马宏忠.同步电机定子绕组内部故障瞬态分析[J].电力系统及其自动化学报,2010(10):80-85.
    [6]肖丽,孙鹤旭,张培培,刘卫鹏.基于Maxwell和Simplorer8/6极开关磁阻电机绕组短路故障分析与研究[J].微电机,2013(8).