碳纳米管/壳聚糖复合膜修饰电极测定尿酸的研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Determination of uric acid based on carbon nanotube/chitosan composite film modified electrode
  • 作者:徐俊晖 ; 周黄歆 ; 王亚珍
  • 英文作者:XU Junhui;ZHOU Huangxin;WANG Yazhen;Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education,School of Chemistry and Environmental Engineering,Jianghan University;
  • 关键词:尿酸 ; 化学修饰电极 ; 碳纳米管 ; 壳聚糖 ; 循环伏安法
  • 英文关键词:uric acid;;chemically modified electrode;;carbon nanotube;;chitosan;;cyclic voltammetry
  • 中文刊名:HZSZ
  • 英文刊名:Journal of Central China Normal University(Natural Sciences)
  • 机构:江汉大学化学与环境工程学院光电化学材料与器件教育部重点实验室;
  • 出版日期:2019-01-31
  • 出版单位:华中师范大学学报(自然科学版)
  • 年:2019
  • 期:v.53;No.183
  • 基金:光电化学材料与器件教育部重点实验(江汉大学)开放基金项目(JDGD-2016008);; 工业烟尘污染控制湖北省重点实验室开放基金项目(HBIK2016-01)
  • 语种:中文;
  • 页:HZSZ201901010
  • 页数:6
  • CN:01
  • ISSN:42-1178/N
  • 分类号:69-74
摘要
制备了一种碳纳米管/壳聚糖复合膜修饰的玻碳电极,并通过循环伏安法和计时库仑法详细研究了尿酸在复合膜修饰电极上的电化学行为.对诸如支持电解质,溶液pH,富集时间等实验条件进行了优化,结果表明,在pH=3.95 0.1mol/L柠檬酸钠盐支持电解质中,尿酸在复合膜修饰电极上具有良好的电化学响应.相对于裸玻碳电极,尿酸的氧化峰电位负移20mV,峰电流显著提高,锋形更为尖锐,表明复合膜对尿酸的电化学氧化具有一定的催化作用,计时库仑法结果表明尿酸在复合膜修饰电极上为两电子两质子的电子转移过程.尿酸的氧化峰电流与其浓度分别在5.0×10-9~5.0×10-7 mol/L范围内和1.5×10-6~1.0×10-4 mol/L范围内呈良好的线性关系,线性相关系数分别是0.994 7和0.988 4.开路富集120s后,检出限为5.0×10-9 mol/L.将该复合膜修饰电极应用于人体实际尿样中尿酸的测量,结果令人满意.
        The carbon nanotube(CNT)/chitosan composite film modified electrode on a glassy carbon electrode had been fabricated.The electrochemical behavior of uric acid was studied at the composite film electrode by cyclic voltammetry and chronocoulometry in detail.The experimental conditions such as supporting electrolytes,pH and accumulation time were optimized.Compared with the bare glassy carbon electrode,the oxidation peak current of uric acid increased greatly,with the negative peak potential shift of about 20 mV,which indicated that CNT/chitosan composite film modified electrode had agood catalytic effect to the electrochemical oxidation of uric acid in pH=3.95,0.1 mol/L citric acid salt buffer.The electrochemical behavior of uric acid at this composite film electrode was also characterized by chronocoulometry.The results indicated that oxidation of uric acid involves two-proton two-electron transfer process.Cyclic voltammetry experiment results also showed that the oxidative peak current increased linearly with the concentration of uric acid in the range of 5.0×10-9~5.0×10-7 mol/L and 1.5×10-6~1.0×10-4 mol/L,respectively.One regression equation was i(μA)=0.8524 c(μmol/L)+0.1879 with a correlation coefficient of 0.994 7 from 5.0×10-9 to 5.0×10-7 mol/L of UA and another regression equation was i(μA)=0.04285 c(μmol/L)+1.299 with a correlation coefficient of 0.988 4 at the range of UA concentration of 1.5×10-6~1.0×10-4 mol/L.The detection limit was 5.0×10-9 mol/L(S/N=3).The high sensitivity and good selectivity of the composite film electrode was demonstrated by its practical application to the determination of uric acid in urine samples.
引文
[1] POPA E,KUBOTA Y,TRYK D A,et al.Selective voltammetric and amperometric detection of uric acid with oxidized diamond film electrodes[J].Anal Chem,2000,72(7):1724-1727.
    [2] ZEN J M,LAI Y Y,YANG H H,et al.Multiannalyte sensor for the simultaneous determination of hypoxanthine,xanthine and uric acid based on a preanodized nontronite-coated screen-printed electrode[J].Sens Actuators B Chem,2002,84(2):237-244.
    [3] SAQIB M,QI L M,HUI P,et al.Development of luminolN-hydroxyphthalimide chemiluminescence system for highly selective and sensitive detection of superoxide dismutase,uric acid and Co2+[J].Biosens Bioelectron,2018,99(1):519-524.
    [4] ZHAO F Y,WANG Z H,WANG H,et al.Determination of uric acid in human urine by ion chromatography with conductivity detector[J].Chin Chem Lett,2011,22(3):342-345.
    [5] PEROLLJ,SANCHIS P,GRASES F.Determination of uric acid in urine,saliva and calcium oxalate renal calculi by high-performance liquid chromatography/mass spectrometry[J].J Chromatogr B,2005,824(1):175-180.
    [6] SARIKAYS A G,OSMAN B,AM T,et al.Molecularlyimprinted surface plasmon resonance(SPR)sensor for uric acid determination[J].Sens Actuators B Chem,2017,251(14):763-772.
    [7] AMJADI M,HALLAJ T,KOUHI Z.An enzyme-free fluorescent probe based on carbon dots-MnO2nanosheets for determination of uric acid[J].J Photochem Photobio A Chem,2018,356(4):603-609.
    [8] DEY M K,SATPATI A K.Functionalised carbon nano spheres modified electrode for simultaneous determination of dopamine and uric acid[J].J Electroanal Chem,2017,787(2):95-102.
    [9] YU H W,JIANG J H,ZHANG Z,et al.Preparation of quantum dots CdTe decorated graphene composite for sensitive detection of uric acid and dopamine[J].Anal Biochem,2017,518(2):92-99.
    [10] ZANG Y H,LEI W,XU Y J,et al.Simultaneous detection of dopamine and uric acid using apoly(l-lysine)/graphene oxide modified electrode[J].Nanomaterials,2016,6(10):178-194.
    [11] IIJIMA S.Helical microtubules of graphitic carbon[J].Nature,1991,354(6348):56-58.
    [12] PAN H,LI J,FENG Y P.Carbon nanotubes for supercapacitor[J].Nanoscale Res Lett,2010,5(1):654-668.
    [13] BARD A J,FAULKNER L R.Electrochemical Methods:Fundamentals and Applications[M].New York:Wiley,2001,210-341.
    [14] WANG L,BAI J Y,HUANG P F,et al.Selective determination of uric acid in the presence of ascorbic acid using a penicillamine self-assembled gold electrode[J].Microchim Acta,2007,158(1-2):73-78.
    [15] WANG Y Z.The electrochemical behavior of uric acid at the L-cysteine self-assembled gold electrode and its application[J].Microchim Acta,2011,172(3-4):419-424.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700