摘要
为建立检测烟用材料中(烟用接装纸、水基胶和香料)铜含量的微波消解-石墨炉原子吸收光谱方法,采用单因素试验对样品前处理条件和分析测试条件进行优化,得到适宜的灰化温度和原子化温度分别为750℃,1900℃;在优选的参数下,检出限和定量限分别为0.031μg/L和0.103μg/L,重复测试的变异系数小于3%,平均回收率范围在98.50%~103.06%。结果表明,该法具有较好的重复性和准确性,适合于烟用材料中铜的测定。
A method to determine copper content in tobacco materials(tipping paper,water-based adhesives and fragrances)using microwave digestion and graphite furnace atomic absorption spectrometry is developed.Experimental conditions are optimized.Ashing temperature and atomization temperature are 750℃and 1 900℃.Under optimum conditions,the detection limit and quantification limit are 0.031μg/L and 0.103μg/L,the variation coefficient is less than 3%and the range of average recovery ratio is 98.50%~103.06%.The results show that the method has good reproducibility and accuracy for the determination of copper in tobacco materials.
引文
[1]王明锋,朱保坤,王文元,等.差减法测定卷烟烟气中7种重金属质量分数[J].云南农业大学学报(自然科学版),2014,29(5):695-700.
[2]杨永建,刘芳,李永忠,等.烟叶重金属及砷限量标准制订研究初探[J].云南农业大学学报(自然科学版),2007,22(4):525-530,536.
[3]黄海涛,孔维松,陈章玉,等.卷烟抽吸过程中重金属元素迁移率的研究[G]//云南省烟草学会2006年学术年会论文集.昆明:云南省烟草学会,2006:75-81.
[4]陈庆华,陈玉成.吸烟过程中的重金属来源解析及预防[J].微量元素与健康研究,2005,22(5):47-49.
[5]宋旭艳,熊宏春,马舒翼,等.冷阱捕获-ICP-MS测定卷烟主流烟气中痕量金属元素[J].河南农业大学学报,2016,50(2):219-223.
[6]李辉,吴建伟,李滟芳,等.ICP-MS法同时测定卷烟主流烟气中的7种痕量元素[J].中国测试,2015(4):46-49.
[7]刘晓燕,顾晓霞.测定会理烤烟中铜、锰的含量[J].广州化工,2016,44(15):123-125.
[8]胡秋芬,张艳宏,王森,等.微波消化-原子吸收法测定卷烟中的钾、钠、钙、镁、铜、铁、锌、铅的研究[J].玉溪师范学院学报,2007,23(3):48-52.
[9]聂根新,罗林广,何宽信,等.微波消解原子吸收法测定烟叶中铜、铁、锰、锌、钙、镁、钾含量[J].江西农业学报,2004,16(2):43-45.
[10]索卫国,胡清源,陈再根,等.ICP-MS法同时测定卷烟纸中元素铬、镍、铜、砷、硒、镉、铅[J].应用化学,2008,25(2):208-211.
[11]王浩雅,马金晶,卢伟,等.微波消解-ICP-MS测定烟叶中的营养元素[J].江苏农业科学,2012,40(9):276-278.
[12]施红林,杨光宇,李忠,等.高效液相色谱法测定烟草中的铁、钴、镍、铜、锌、锰[J].中国烟草学报,2003,9(1):5-8.