摘要
针对高炉铜冷却壁热面渣皮稳定性下降、脱落的现象,对河南济源钢铁(集团)有限公司高炉渣的软熔性和流动性进行了试验研究。结果表明:ω_(FeO)为15%、碱度为1时,随着ω_(K_2O)的增加,高炉渣的软熔温度不断下降,炉渣稳定性变差;ω_(CaF_2)的增加对渣皮的稳定性影响不显著。
As for the fact that the slag skull of hotface on copper stave of blast furnace(BF) is unstable and falls off frequently, the test study on the softening melting properties and liquidity of BF primary slag and medium-term slag was carried out. The results showed that the stability of BF slag became worse and the softening melting temperature continues to drop with the increase of ω_(K_2O) while the basicity was 1 and ω_(FeO) was 15%; but the content of calcium fluoride increasing could not strongly affect the softening melting properties of BF slag.
引文
[1]王海宝,张洪宇,车与满.鞍钢铜冷却壁高炉的热负荷管理[J].炼铁,2008,27(2):1-4.
[2]魏丽.我国高炉使用铜冷却壁10年来的回顾[J].炼铁,2012,31(3):13-15.
[3]毕忠新,朱建秋.2500 m~3钒钛矿冶炼高炉的优化实践[N].中国冶金报,2011-8-4(B02).
[4]刘云彩.高炉渣皮脱落分析[J].中国冶金,2014,24(12):32-35.
[5]张建良,王志宇.焦克新等高炉炉缸耐火材料抗渣侵蚀性及挂渣性[J].钢铁,2015,50(11):27-31.
[6]张芳,安胜利,罗果萍,等.高炉初渣及中间渣软熔性质的研究[J].钢铁钒钛,2014,35(5):98-102.