摘要
研究了主动式活性炭吸附土壤氡气测量方法。在氡室条件下,利用设计的取样装置对主动式活性炭吸附法中活性炭吸附能力、取样量、取样速度等影响因素及测量参数开展了实验研究,并进行了该方法与其他3种不同土壤氡气测量方法的野外对比实验,相对于传统的被动式活性炭累积测氡,该方法工作效率高,为土壤氡气测量在勘探找矿、环境监测等领域的应用提供了一种全新的测量方式。
Based on the overview of soil radon measurement methods,the active activated carbon adsorption method was studied at first,And then,the factors affecting the activated carbon adsorption capacity,adsorption speed,adsorption time of the sample was tested in radon chamber,the experiments of four different instruments using the parameters from radon chamber test were finished and compared.Compared to the traditional activated carbon accumulation passive radon measurement,this method greatly improved the working efficiency,and laid foundation for further environmental monitoring,exploration and prospecting.
引文
[1]EJ/T 605-1991,氡及其子体测量规范[S].北京:中国标准化出版社,1991.
[2]方方,贾文懿,周蓉生.氡气测量研究[J].核技术,1999,22(4):218-222.
[3]赵桂芝,肖德涛.土壤氡浓度的测量方法现状[J].核电子学与探测技术,2007,27(3):583-588.
[4]邱元德,童运福.活性炭测氡法的特点[J].核技术,1996,19(9):554-559.
[5]高超.一种土壤氡浓度测量方法的改进[J].环境科学与管理,2010,35(11):135-139.
[6]ISO 11665-5-2012.Measurement of radioactivity in the environment-Air:radon-222[S].International Organization for Standardization,2012.
[7]梅爱华.活性炭盒法测室内空气氡浓度研究综述[J].建筑监督检测与造价,2014,7(6):48-50.