摘要
为解决大气透射能见度仪的测试精度问题,对透射式能见度仪建立了简单的数学模型,从理论上分析了仪器测试的误差来源;并以提高接收机的稳定性和延长基线为思路提出了一系列提高能见度仪测试精度的解决方案。为了验证该方案的有效性,安排了2套设备在同一地点做了对比测试。测试结果表明:2套参试仪器的测量值总体走向是一致的,在能见度较高且快速变化时,虽然2台设备测试数据出现偏离,但已经达到了气象部门对透射式能见度仪的精度指标的要求,证明了数学模型的有效性。
In order to improve the accuracy of atmosphere transmission meter,a math model is established,in which the error theoretical analysis can be conducted,and then series of solutions are put forward including of both enhancing the stability of receiver and prolong the base line. Then two set instruments are installed in same site and as work together to verify the effectiveness of the solution. The test data showthat the data trend is well consistent with each other,although the deviation still exists when MOR is high and changes rapidly,but still within the accuracy limit of meteorological bureau. Thus the effectiveness of the math model is proved.
引文
[1]符荣鑫,郑玉峰,聂梦松,等.基于透射法的空气能见度测量[J].实验技术与管理,2013,30(11):76-78.
[2]蔡琴,甘志,徐智勇.能见度测试的系统偏差分析[J].成都工业学院学报,2015(2):45-47.
[3]唐慧强,鞠琳,鲍婷婷.基于WSN的透射式能见度检测系统设计[J].仪表技术与传感器,2011(1):57-59.
[4]傅刚,李晓岚,魏娜.大气能见度研究[J].中国海洋大学学报(自然科学版),2009,39(5):855-863.
[5]程绍荣,魏全忠,吕军.一种实用型大气透射式能见度仪的研制[J].光电工程,2011,38(2):144-147.