用户名: 密码: 验证码:
活性污泥模型模拟污水处理厂运行的工程应用研究进展
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Advances in engineering application research of activated sludge model simulating sewage treatment plant operation
  • 作者:丁婉晴 ; 薄涛 ; 丁彬彬 ; 张晓文
  • 英文作者:Ding Wanqing;Bo Tao;Ding Binbin;Zhang Xiaowen;Harbin Institute of Technology (Shenzhen) Environmental Science and Engineering Research Center;Shenzhen Zhongtao Environmental Engineering Technology Co., Ltd.;Harbin Institute of Technology (Shenzhen) School of Computer Science and Technology;
  • 关键词:污水处理 ; 活性污泥模型 ; 模型校准 ; 工艺优化
  • 英文关键词:Sewage treatment;;Activated sludge model;;Model calibration;;Process optimization
  • 中文刊名:NMHB
  • 英文刊名:Environment and Development
  • 机构:哈尔滨工业大学(深圳)环境科学与工程研究中心;深圳市中涛环保工程技术有限公司;哈尔滨工业大学(深圳)计算机科学与技术学院;
  • 出版日期:2018-09-28
  • 出版单位:环境与发展
  • 年:2018
  • 期:v.30;No.146
  • 基金:深圳市科技创新委员会技术攻关项目资助,项目编号:JSGG20160429154945736,项目名称:基于氮平衡的污水处理厂总氮去除关键技术研发
  • 语种:中文;
  • 页:NMHB201809012
  • 页数:2
  • CN:09
  • ISSN:15-1369/X
  • 分类号:35+37
摘要
污水处理行业快速地由污水处理模式向资源回收模式转变,活性污泥模型(ASMs)应运而生。本文首先概括了污水厂模型建立的一般步骤;然后结合国内外工程实例介绍了ASMs的发展过程;最后阐述了ASMs模拟污水处理厂运行的重大意义,并对研究的发展方向进行了展望。
        The sewage treatment industry has rapidly changed from a sewage treatment mode to a resource recovery model, and activated sludge models(ASMs) have emerged. This paper first summarizes the general steps of the establishment of the wastewater treatment plant model; then combined with domestic and foreign engineering examples to introduce the development process of ASMs; finally, the significance of ASMs simulating the operation of sewage treatment plants is explained, and the development direction of the research is prospected.
引文
[1]ELAWWAD A, ZAGHLOUL M, ABDEL-HALIM H. Simulation of municipal-industrial full scale WWTP in an arid climate by application of ASM3[J]. Journal of Water Reuse and Desalination, 2017,7(1):37-44.
    [2]YAO-YU ZHANG J H A M. Simulation and Analysis of the Capacity of A2/O Wastewater Treatment Plant Based on ASM2D Model:2016 2nd International Conference on Sustainable Energy and Environmental Engineering, 2016[C].
    [3]MACHADO V C, LAFUENTE J, BAEZA J A. Activated sludge model 2d calibration with full-scale WWTP data:comparing model parameter identifiability with influent and operational uncertainty[J].Bioprocess and Biosystems Engineering, 2014,37(7):1271-1287.
    [4]DERCOJ,?ERNOCHOVáL,KRCHO=,etal.Dynamic simulations of waste water treatment plant operation[J]. Chemical Papers, 2011,65(6).
    [5]De GUSSEM K, WAMBECQ T, ROELS J, et al. Cost optimisation and minimisation of the environmental impact through life cycle analysis of the waste water treatment plant of Bree(Belgium)[J].Water Science&Technology, 2011,63(1):164.
    [6]FANG F, NI B, XIE W, et al. An integrated dynamic model for simulating a full-scale municipal wastewater treatment plant under fluctuating conditions[J]. Chemical Engineering Journal,2010,160(2):522-529.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700