用户名: 密码: 验证码:
Uranium and other heavy toxic elements distribution in the drinking water samples of SW-Punjab, India
详细信息    查看全文
文摘
In the present investigations, Laser Fluorimetry technique has been used for the microanalysis of uranium content in drinking water samples collected from different sources like the hand pumps, tube wells of various depths from wide range of locations in the four districts of SW-Punjab, India. The purpose of this study was to investigate the uranium concentration levels of ground water being used for drinking purposes and to determine its health effects, if any, to the local population of this region. Corresponding radiological and chemical risks have also been calculated for the uranium concentrations in ground water samples. Some other heavy elements have also been analysed using the Atomic Absorption Spectrometry. In this region, uranium concentration in 498 drinking water samples has been found to vary between 0.5–579 μgl−1with an average of 73.5 μgl−1. Data analysis revealed that 338 of 498 samples had uranium concentration higher than recommended safe limit of 30 μgl−1 (WHO, 2011) while 216 samples exceeded the threshold of 60 μgl−1 recommended by AERB, DAE, India, 2004.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700